Safety Cabinet Internal Circulation Filtering System
This safety and environmental improvement equipment is mounted outside the safety storage box, which stores various flammable and corrosive chemicals used in production processes, experiments, and research at chemical and agrochemical laboratories, including government research institutes, schools, and companies. It dryly purifies organic and inorganic gases generated inside.Model | SMCICFS-Y2 |
---|---|
Size (W*D*H)(mm) | 420 * 320 * 240 |
Rated Voltage | AC220V, 50/60Hz |
Power Consumption | 30W |
Weight | 13.5kg |
Warranty | 1 Year |
COMPOSITION
FEATURES
EFFECTS
Quality standards for internal circulation filtering system
Product | Test items (unit) | Maximum value for application | Comparable specifications | Deliverable specifications | |||||
Standard criteria | |||||||||
Specifications | Applicable criteria | Specifications | Applicable criteria | Specifications | Applicable criteria | ||||
Internal Circulation Filtering System(SMCICFS-Y2) | Power Consumption(W) | 17.9 | Test Report (PC21-01269K) | - | - | Power consumption of 300 or less at rated input for 30 minutes | Company-presented standard test method * Product specifications 6-2-1. Refer to test method |
||
Insulation Resistance(GΩ) | Above 1.79 | - | Above 1 | ||||||
Voltage Withstand(-) | Withstands test voltage | - | Withstands test voltage with no insulation breakdown | ||||||
Film Adhesion (-) | No peeling | Test Report (CT21-133805K) | No peeling | KS M ISO 2409 | No peeling | KS M ISO 2409 | |||
Film Thickness(μm) | 61 | Above 40 | KS M ISO 2808 | Above 50 | KS M ISO 2808 | ||||
Normal operation after drop impact(-) | No abnormalities | Test Report (TBK-2020-000550) | - | - | No abnormalities in operation after impact | Company-presented standard test method * Product specifications 6-2-1. Refer to test method |
|||
Condition treatment test | Normal operation after high temperature (50℃) treatment | No abnormalities | - | - | No abnormalities in operation after 24 hours of conditioning | ||||
Normal operation after low temperature (-10℃) treatment (-) | No abnormalities | - | |||||||
Deodorization test (%) | Deodorization rate of harmful substances above 88.5 | Test Report (21-064773-01-2) | Above 60 | KOUVA AS 02 | Hazardous substance removal efficiency of above 70 | KOUVA AS 02 | |||
Lifespan Performance (L) (gas removal capacity) | Gas removal capacity above 8 | Test Report (PC21-01263K) | Above 5 | SPS-KTC-B6870-6410 | Above 5 (based on test air volume: 1 m3/min) | SPS-KTC-B6870-6410 | |||
Acid gas removal performance | Acid gas removal rate above 95 | Test Report (20190707) | Above 60 | Air Pollutant Emission Standards | Removal rate of above 80(Air Pollutant Emission Standards) | Company-presented standard test method * Product specifications 6-2-2. Refer to test method |
|||
TVOC reduction capacity (%) | Initial TVOC concentration (mg/m3) | 0.57 | Test Report (TBK-2020-000550) | Below 1 ~ 0.4 | Indoor Air Quality Advisory Standards | Below 1 ~ 0.4 (Indoor Air Quality Advisory Standards) | |||
TVOC concentration after spraying(mg/m3) | 23.25 | ||||||||